Calculate Pump Head Pressure

Add up your fittings, tubing and vertical lift to get the total dynamic head your pump has to overcome.

1Your plumbing
Add up the equivalent length of every fitting (Chart 1 below).
For your flow and tubing size (Chart 2 below).
Height from the water surface to the outlet.

How it's calculated

  • Equivalent pipe length = fitting length + tubing length
  • Friction head = equivalent pipe length × friction loss
  • Total dynamic head (TDH) = vertical head + friction head
Chart 1: equivalent length in feet of PVC fittings (elbows, adapters, tees, check valve) by fitting size
Chart 1: fitting lengths
Chart 2: friction loss by flow in gallons per hour and tubing size
Chart 2: friction loss
Chart 3: pump flow against total dynamic head
Chart 3: pump performance